ONEIC.US

PZE X4V Series

The PZE X4V series from Pilz is a line of safety relays designed for industrial control systems that require precise timing and reliable safety functions. These relays are commonly found in machinery and factory automation where safety interlocks and emergency stop functions are critical. If you're working on a project involving safety-critical machinery, these relays are a go-to solution. One thing worth noting is their ability to handle both safety-related and non-safety signals. This dual functionality makes them versatile and space-efficient, reducing the need for separate relays. Engineers tend to reach for this when they need a compact solution that can manage both regular and safety signals without compromising on performance or reliability. Another practical benefit is the built-in delay function, which is essential for safety circuits that require a specific time delay before a safety action is triggered. This feature helps in avoiding false triggering due to transient signals, ensuring that only genuine safety issues are addressed

The PZE X4V series from Pilz is a line of safety relays designed for industrial control systems that require precise timing and reliable safety functions. These relays are commonly found in machinery and factory automation where safety interlocks and emergency stop functions are critical. If you're working on a project involving safety-critical machinery, these relays are a go-to solution. One thing worth noting is their ability to handle both safety-related and non-safety signals. This dual functionality makes them versatile and space-efficient, reducing the need for separate relays. Engineers tend to reach for this when they need a compact solution that can manage both regular and safety signals without compromising on performance or reliability. Another practical benefit is the built-in delay function, which is essential for safety circuits that require a specific time delay before a safety action is triggered. This feature helps in avoiding false triggering due to transient signals, ensuring that only genuine safety issues are addressed

Series Images (1)

Frequently Asked Questions

Content generated by AI, for reference only
Loading...
03

PZE X4V - Part List

7 parts in total

Safety Category

Voltage - Supply

Mfr Part #Quantity AvailablePriceCategorySafety CategorySafety Outputs and TypePower - RatedNumber of PolesVoltage - SupplyNumber of ChannelsContact Rating (Current)Contact Rating @ VoltageDepthWidthLengthTerminal TypeMounting StyleSize / DimensionControl/Display TypeNumber of Safety OutputsNormal State ConfigurationOperating Temperature
541: $1,078.8812-Category 3 EN 954-1, Category 3 PLe EN ISO 13849-1, CCC, cULus, EN 60947-5-1, EN 61000-6-2, EN IEC 62061 PFH 2.48E-09, EN IEC 62061 SIL CL 2, IEC 61511 PFD 1.47E-05, IEC 61511 SIL 2, TUV4NO2.5 W4P (Safety)24 V dc16 A24 V dc, 240 V ac121mm22.5mm87mmScrewDIN Rail Mount87 x 22.5 x 121 mm24 V04NO (Safety)+55°C
541: $1,078.8812-Category 3 EN 954-1, Category 3 PLe EN ISO 13849-1, CCC, cULus, EN 60947-5-1, EN 61000-6-2, EN IEC 62061 PFH 2.48E-09, EN IEC 62061 SIL CL 2, EN ISO 13849-1:2006 20, IEC 61511 PFD 1.47E-05, IEC 61511 SIL 2, TUV, Type 3 A EN 5744NO2.5 W4P (Safety)24 V16 A24 V dc, 240 V ac121mm22.5mm87mmScrewDIN Rail Mount87 x 22.5 x 121 mm24 V04NO (Safety)+55°C
PZE X4VP8 24VDC 4n/o
PZE X4VP8 24VDC 4n/o

Pilz GmbH & Co. KG

0-------------------
0-------------------
0-------------------
0-------------------